https://sekels-magnetic-shielding.eu/index.php?title=Messsysteme_und_Dienstleistungen&feed=atom&action=history
Messsysteme und Dienstleistungen - Versionsgeschichte
2024-03-29T13:36:03Z
Versionsgeschichte dieser Seite in Sekels Magnetic Shielding
MediaWiki 1.31.0
https://sekels-magnetic-shielding.eu/index.php?title=Messsysteme_und_Dienstleistungen&diff=498&oldid=prev
Nmrt am 13. November 2018 um 10:29 Uhr
2018-11-13T10:29:37Z
<p></p>
<table class="diff diff-contentalign-left" data-mw="interface">
<col class="diff-marker" />
<col class="diff-content" />
<col class="diff-marker" />
<col class="diff-content" />
<tr class="diff-title" lang="de">
<td colspan="2" style="background-color: #fff; color: #222; text-align: center;">← Nächstältere Version</td>
<td colspan="2" style="background-color: #fff; color: #222; text-align: center;">Version vom 13. November 2018, 10:29 Uhr</td>
</tr><tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l45" >Zeile 45:</td>
<td colspan="2" class="diff-lineno">Zeile 45:</td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Messung der Koerzitivfeldstärke</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Messung der Koerzitivfeldstärke</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Bestimmung der Ummagnetisierungsverluste</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Bestimmung der Ummagnetisierungsverluste</div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;"></ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">{{Sekels}}</ins></div></td></tr>
</table>
Nmrt
https://sekels-magnetic-shielding.eu/index.php?title=Messsysteme_und_Dienstleistungen&diff=290&oldid=prev
Nmrt am 28. Juli 2018 um 12:36 Uhr
2018-07-28T12:36:24Z
<p></p>
<table class="diff diff-contentalign-left" data-mw="interface">
<col class="diff-marker" />
<col class="diff-content" />
<col class="diff-marker" />
<col class="diff-content" />
<tr class="diff-title" lang="de">
<td colspan="2" style="background-color: #fff; color: #222; text-align: center;">← Nächstältere Version</td>
<td colspan="2" style="background-color: #fff; color: #222; text-align: center;">Version vom 28. Juli 2018, 12:36 Uhr</td>
</tr><tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l10" >Zeile 10:</td>
<td colspan="2" class="diff-lineno">Zeile 10:</td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>Abbildung 15 zeigt die Feldverteilung in einer zylindrischen Abschirmung aus MUMETALL® mit einem Loch im rechten Seitendeckel.</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>Abbildung 15 zeigt die Feldverteilung in einer zylindrischen Abschirmung aus MUMETALL® mit einem Loch im rechten Seitendeckel.</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;"></del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">==Kompetenzen und Messdienstleistungen==</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">* Magnetische und mechanische Qualitätskontrolle gefertigter Abschirmungen</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">* Schirmfaktormessung als Auftragsdienstleistung</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">* Orts- und frequenzaufgelöste Schirmfaktormessungen in Abschirmungen (bis zu 40 Kanäle)</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">* Vor-Ort-Messungen bei „größeren“ Abschirmproblemen</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">* Messungen der magnetischen Feldbelastung von Geräten, Anlagen oder Umgebungen (nach BGV</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">B11, 26. BImSchV, etc.)</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">* Messungen der magnetischen Störaussendungen im niederfrequenten Bereich</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">* Problemangepasste Sensorauswahl (Hall-Elemente, Search-Coils, Fluxgates etc.)</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">* Optimierungsanalysen bereits bestehender Abschirmsysteme</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">* Entmagnetisierungen (elektromagnetisch oder thermisch)</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">* Störbeeinflussungsmessungen von elektronischen Geräten unter aufgeprägten Magnetfeldern</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">* Materialcharakterisierung durch Hysteresemessung</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">* Messung der Koerzitivfeldstärke</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">* Bestimmung der Ummagnetisierungsverluste</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>{| class="wikitable"</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>{| class="wikitable"</div></td></tr>
<tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l44" >Zeile 44:</td>
<td colspan="2" class="diff-lineno">Zeile 28:</td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>30_p3.jpg|</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>30_p3.jpg|</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div></gallery></div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div></gallery></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;"></ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;"></ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">==Kompetenzen und Messdienstleistungen==</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">* Magnetische und mechanische Qualitätskontrolle gefertigter Abschirmungen</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">* Schirmfaktormessung als Auftragsdienstleistung</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">* Orts- und frequenzaufgelöste Schirmfaktormessungen in Abschirmungen (bis zu 40 Kanäle)</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">* Vor-Ort-Messungen bei „größeren“ Abschirmproblemen</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">* Messungen der magnetischen Feldbelastung von Geräten, Anlagen oder Umgebungen (nach BGV</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">B11, 26. BImSchV, etc.)</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">* Messungen der magnetischen Störaussendungen im niederfrequenten Bereich</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">* Problemangepasste Sensorauswahl (Hall-Elemente, Search-Coils, Fluxgates etc.)</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">* Optimierungsanalysen bereits bestehender Abschirmsysteme</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">* Entmagnetisierungen (elektromagnetisch oder thermisch)</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">* Störbeeinflussungsmessungen von elektronischen Geräten unter aufgeprägten Magnetfeldern</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">* Materialcharakterisierung durch Hysteresemessung</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">* Messung der Koerzitivfeldstärke</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">* Bestimmung der Ummagnetisierungsverluste</ins></div></td></tr>
</table>
Nmrt
https://sekels-magnetic-shielding.eu/index.php?title=Messsysteme_und_Dienstleistungen&diff=289&oldid=prev
Nmrt am 28. Juli 2018 um 12:35 Uhr
2018-07-28T12:35:46Z
<p></p>
<table class="diff diff-contentalign-left" data-mw="interface">
<col class="diff-marker" />
<col class="diff-content" />
<col class="diff-marker" />
<col class="diff-content" />
<tr class="diff-title" lang="de">
<td colspan="2" style="background-color: #fff; color: #222; text-align: center;">← Nächstältere Version</td>
<td colspan="2" style="background-color: #fff; color: #222; text-align: center;">Version vom 28. Juli 2018, 12:35 Uhr</td>
</tr><tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l27" >Zeile 27:</td>
<td colspan="2" class="diff-lineno">Zeile 27:</td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Bestimmung der Ummagnetisierungsverluste</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Bestimmung der Ummagnetisierungsverluste</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">{| class="wikitable"</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">|-</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">| '''Spulensystem''' || 1000 mm || 2000 mm || 300 mm Hochfeldspule</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">|-</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">| '''Frequenzbereich''' || DC und 0,1 – 2000 Hz || DC und 0,1 – 2000 Hz || DC</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">|-</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">| '''Amplitudenbereich''' || 7,74 mT (DC ) – 0,08 mT (2000 Hz) || 3,34 mT (DC ) – 0,05 mT (2000 Hz) || Nennwert: 40 mT (kurzfristig: 77 mT)</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">|}</ins></div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div><gallery caption="Abb. 15: Räumliche Feldverteilung in einem Abschirmzylinder mit Öffnung im Deckel. Die Feldstärken können sowohl nach Betrag als auch nach Richtung dargestellt werden. Die senkrechte Achse ist jeweils unterschiedlich</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div><gallery caption="Abb. 15: Räumliche Feldverteilung in einem Abschirmzylinder mit Öffnung im Deckel. Die Feldstärken können sowohl nach Betrag als auch nach Richtung dargestellt werden. Die senkrechte Achse ist jeweils unterschiedlich</div></td></tr>
</table>
Nmrt
https://sekels-magnetic-shielding.eu/index.php?title=Messsysteme_und_Dienstleistungen&diff=288&oldid=prev
Nmrt am 28. Juli 2018 um 12:32 Uhr
2018-07-28T12:32:39Z
<p></p>
<table class="diff diff-contentalign-left" data-mw="interface">
<col class="diff-marker" />
<col class="diff-content" />
<col class="diff-marker" />
<col class="diff-content" />
<tr class="diff-title" lang="de">
<td colspan="2" style="background-color: #fff; color: #222; text-align: center;">← Nächstältere Version</td>
<td colspan="2" style="background-color: #fff; color: #222; text-align: center;">Version vom 28. Juli 2018, 12:32 Uhr</td>
</tr><tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l26" >Zeile 26:</td>
<td colspan="2" class="diff-lineno">Zeile 26:</td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Messung der Koerzitivfeldstärke</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Messung der Koerzitivfeldstärke</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Bestimmung der Ummagnetisierungsverluste</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Bestimmung der Ummagnetisierungsverluste</div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;"></ins></div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div><gallery caption="Abb. 15: Räumliche Feldverteilung in einem Abschirmzylinder mit Öffnung im Deckel. Die Feldstärken können sowohl nach Betrag als auch nach Richtung dargestellt werden. Die senkrechte Achse ist jeweils unterschiedlich</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div><gallery caption="Abb. 15: Räumliche Feldverteilung in einem Abschirmzylinder mit Öffnung im Deckel. Die Feldstärken können sowohl nach Betrag als auch nach Richtung dargestellt werden. Die senkrechte Achse ist jeweils unterschiedlich</div></td></tr>
</table>
Nmrt
https://sekels-magnetic-shielding.eu/index.php?title=Messsysteme_und_Dienstleistungen&diff=287&oldid=prev
Nmrt am 28. Juli 2018 um 12:32 Uhr
2018-07-28T12:32:09Z
<p></p>
<table class="diff diff-contentalign-left" data-mw="interface">
<col class="diff-marker" />
<col class="diff-content" />
<col class="diff-marker" />
<col class="diff-content" />
<tr class="diff-title" lang="de">
<td colspan="2" style="background-color: #fff; color: #222; text-align: center;">← Nächstältere Version</td>
<td colspan="2" style="background-color: #fff; color: #222; text-align: center;">Version vom 28. Juli 2018, 12:32 Uhr</td>
</tr><tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l27" >Zeile 27:</td>
<td colspan="2" class="diff-lineno">Zeile 27:</td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Bestimmung der Ummagnetisierungsverluste</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Bestimmung der Ummagnetisierungsverluste</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'>−</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><gallery caption=Abb. 15: Räumliche Feldverteilung in einem Abschirmzylinder mit Öffnung im Deckel. Die Feldstärken können sowohl nach Betrag als auch nach Richtung dargestellt werden. Die senkrechte Achse ist jeweils unterschiedlich</div></td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><gallery caption=<ins class="diffchange diffchange-inline">"</ins>Abb. 15: Räumliche Feldverteilung in einem Abschirmzylinder mit Öffnung im Deckel. Die Feldstärken können sowohl nach Betrag als auch nach Richtung dargestellt werden. Die senkrechte Achse ist jeweils unterschiedlich</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>skaliert." widths=180px></div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>skaliert." widths=180px></div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>028_b01.jpg|</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>028_b01.jpg|</div></td></tr>
</table>
Nmrt
https://sekels-magnetic-shielding.eu/index.php?title=Messsysteme_und_Dienstleistungen&diff=286&oldid=prev
Nmrt am 28. Juli 2018 um 12:31 Uhr
2018-07-28T12:31:46Z
<p></p>
<table class="diff diff-contentalign-left" data-mw="interface">
<col class="diff-marker" />
<col class="diff-content" />
<col class="diff-marker" />
<col class="diff-content" />
<tr class="diff-title" lang="de">
<td colspan="2" style="background-color: #fff; color: #222; text-align: center;">← Nächstältere Version</td>
<td colspan="2" style="background-color: #fff; color: #222; text-align: center;">Version vom 28. Juli 2018, 12:31 Uhr</td>
</tr><tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l26" >Zeile 26:</td>
<td colspan="2" class="diff-lineno">Zeile 26:</td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Messung der Koerzitivfeldstärke</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Messung der Koerzitivfeldstärke</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Bestimmung der Ummagnetisierungsverluste</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>* Bestimmung der Ummagnetisierungsverluste</div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;"></ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;"><gallery caption=Abb. 15: Räumliche Feldverteilung in einem Abschirmzylinder mit Öffnung im Deckel. Die Feldstärken können sowohl nach Betrag als auch nach Richtung dargestellt werden. Die senkrechte Achse ist jeweils unterschiedlich</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">skaliert." widths=180px></ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">028_b01.jpg|</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">029_b02.jpg|</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">30_p1.jpg|</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">30_p2.jpg|</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">30_p3.jpg|</ins></div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;"></gallery></ins></div></td></tr>
</table>
Nmrt
https://sekels-magnetic-shielding.eu/index.php?title=Messsysteme_und_Dienstleistungen&diff=278&oldid=prev
Nmrt am 28. Juli 2018 um 11:07 Uhr
2018-07-28T11:07:05Z
<p></p>
<table class="diff diff-contentalign-left" data-mw="interface">
<col class="diff-marker" />
<col class="diff-content" />
<col class="diff-marker" />
<col class="diff-content" />
<tr class="diff-title" lang="de">
<td colspan="2" style="background-color: #fff; color: #222; text-align: center;">← Nächstältere Version</td>
<td colspan="2" style="background-color: #fff; color: #222; text-align: center;">Version vom 28. Juli 2018, 11:07 Uhr</td>
</tr><tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l1" >Zeile 1:</td>
<td colspan="2" class="diff-lineno">Zeile 1:</td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;">[[Datei:027_helmholz_spulen.jpg|frame|rechts|Helmholtz-Messplatz für die Messung von Abschirmfaktoren]]</ins></div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>Neben theoretischen Berechnungsmöglichkeiten können wir Abschirmungen auch experimentell beurteilen. Die SEKELS GmbH verfügt über ein gut ausgestattetes Labor zur Materialcharakterisierung.</div></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"><div>Neben theoretischen Berechnungsmöglichkeiten können wir Abschirmungen auch experimentell beurteilen. Die SEKELS GmbH verfügt über ein gut ausgestattetes Labor zur Materialcharakterisierung.</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f8f9fa; color: #222; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;"></td></tr>
</table>
Nmrt
https://sekels-magnetic-shielding.eu/index.php?title=Messsysteme_und_Dienstleistungen&diff=276&oldid=prev
Nmrt: Die Seite wurde neu angelegt: „Neben theoretischen Berechnungsmöglichkeiten können wir Abschirmungen auch experimentell beurteilen. Die SEKELS GmbH verfügt über ein gut ausgestattetes La…“
2018-07-28T11:02:31Z
<p>Die Seite wurde neu angelegt: „Neben theoretischen Berechnungsmöglichkeiten können wir Abschirmungen auch experimentell beurteilen. Die SEKELS GmbH verfügt über ein gut ausgestattetes La…“</p>
<p><b>Neue Seite</b></p><div>Neben theoretischen Berechnungsmöglichkeiten können wir Abschirmungen auch experimentell beurteilen. Die SEKELS GmbH verfügt über ein gut ausgestattetes Labor zur Materialcharakterisierung.<br />
<br />
Die Auslegung von magnetischen Abschirmungen und Magnetsystemen alleine durch Simulationstools und Berechnungen führt oftmals zu unangenehmen Überraschungen. Bereits geringfügige Veränderungen einer einfachen Geometrie (z. B. durch Öffnungen, Luftspalte, Überlappungen, Bohrungen, Verschweißungen etc.) können die Flussleitungseigenschaften massiv verändern. Mit unserem Messlabor können wir Sie bei der Optimierung Ihrer Abschirmung unterstützen.<br />
<br />
Zur Aufprägung externer Magnetfelder verfügt die SEKELS GmbH über eine Auswahl verschiedener Spulen. Dazu gehören Helmholtz-Spulenpaare mit Durchmessern von 1 m und 2 m für Messungen an größeren Abschirmgeometrien mit höchster Genauigkeit sowie Solenoidspulen für sehr starke Magnetfelder. Die damit erzielbaren Feldeigenschaften entnehmen Sie bitte der untenstehenden Tabelle.<br />
<br />
Neben schnellen Routinemessungen mit wenigen Messpunkten können Wiederholungsuntersuchungen auch mit hoher räumlicher Auflösung durchgeführt werden, die zudem mehrere Frequenzen und Feldamplituden abdecken können. Dies ist z. B. notwendig, um sich ein genaues Bild der (Rest)Feldverteilung gerade an kritischen Stellen zu machen.<br />
<br />
Abbildung 15 zeigt die Feldverteilung in einer zylindrischen Abschirmung aus MUMETALL® mit einem Loch im rechten Seitendeckel.<br />
<br />
<br />
==Kompetenzen und Messdienstleistungen==<br />
* Magnetische und mechanische Qualitätskontrolle gefertigter Abschirmungen<br />
* Schirmfaktormessung als Auftragsdienstleistung<br />
* Orts- und frequenzaufgelöste Schirmfaktormessungen in Abschirmungen (bis zu 40 Kanäle)<br />
* Vor-Ort-Messungen bei „größeren“ Abschirmproblemen<br />
* Messungen der magnetischen Feldbelastung von Geräten, Anlagen oder Umgebungen (nach BGV<br />
B11, 26. BImSchV, etc.)<br />
* Messungen der magnetischen Störaussendungen im niederfrequenten Bereich<br />
* Problemangepasste Sensorauswahl (Hall-Elemente, Search-Coils, Fluxgates etc.)<br />
* Optimierungsanalysen bereits bestehender Abschirmsysteme<br />
* Entmagnetisierungen (elektromagnetisch oder thermisch)<br />
* Störbeeinflussungsmessungen von elektronischen Geräten unter aufgeprägten Magnetfeldern<br />
* Materialcharakterisierung durch Hysteresemessung<br />
* Messung der Koerzitivfeldstärke<br />
* Bestimmung der Ummagnetisierungsverluste</div>
Nmrt